Abstract

Efficient Air Conditioning (A/C) system is the key to reducing energy consumption in building operation. In order to decrease the energy consumption in an A/C system, a method to calculate the optimal tube row number of a direct expansion (DX) cooling coil for minimizing the entropy generation in the DX cooling which functioned as evaporator in the A/C system was developed. The optimal tube row numbers were determined based on the entropy generation minimization (EGM) approach. Parametric studies were conducted to demonstrate the application of the analytical calculation method. Optimal tube row number for different air mass flow rates, inlet air temperatures and sensible cooling loads were investigated. It was found that the optimal tube row number of a DX cooling coil was in the range of 5 - 9 under normal operating conditions. The optimal tube row number was less when the mass flow rate and inlet air temperature were increased. The tube row number increased when the sensible cooling load was increased. The exergy loss when using a non-optimal and optimal tube row numbers was compared to show the advantage of using the optimal tube row number. The decrease of exery loss ranged from around 24% to 70%. Therefore the new analytical method developed in this paper offers a good practice guide for the design of DX cooling coils for energy conservation.

KeywordOptimal Tube Row Number Entropy Generation Minimization Direct Expansion (DX) Cooling Coil Building Energy Efficiency
DOI10.4236/jbcpr.2015.32006
URLView source
Language英语English
Citation statistics
Document TypeJournal article
Identifierhttp://repository.uic.edu.cn/handle/39GCC9TT/12002
CollectionResearch outside affiliated institution
Corresponding AuthorXia, Liang
Affiliation
1.Department of Architecture and Built Environment, University of Nottingham Ningbo China, Ningbo, China
2.School of Mathematical Sciences, University of Nottingham Ningbo China, Ningbo, China
3.Department of Civil Engineering, University of Nottingham Ningbo China, Ningbo, China
Recommended Citation
GB/T 7714
Xia, Liang,Yang, Tong,Chan, Yueet al. Optimisation of Direct Expansion (DX) Cooling Coils Aiming to Building Energy Efficiency[J]. Journal of Building Construction and Planning Research, 2015, 3(2): 47-59.
APA Xia, Liang, Yang, Tong, Chan, Yue, Tang, Llewellyn, & Chen, Yung-Tsang. (2015). Optimisation of Direct Expansion (DX) Cooling Coils Aiming to Building Energy Efficiency. Journal of Building Construction and Planning Research, 3(2), 47-59.
MLA Xia, Liang,et al."Optimisation of Direct Expansion (DX) Cooling Coils Aiming to Building Energy Efficiency". Journal of Building Construction and Planning Research 3.2(2015): 47-59.
Files in This Item:
There are no files associated with this item.
Related Services
Usage statistics
Google Scholar
Similar articles in Google Scholar
[Xia, Liang]'s Articles
[Yang, Tong]'s Articles
[Chan, Yue]'s Articles
Baidu academic
Similar articles in Baidu academic
[Xia, Liang]'s Articles
[Yang, Tong]'s Articles
[Chan, Yue]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Xia, Liang]'s Articles
[Yang, Tong]'s Articles
[Chan, Yue]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.