摘要

Efficient Air Conditioning (A/C) system is the key to reducing energy consumption in building operation. In order to decrease the energy consumption in an A/C system, a method to calculate the optimal tube row number of a direct expansion (DX) cooling coil for minimizing the entropy generation in the DX cooling which functioned as evaporator in the A/C system was developed. The optimal tube row numbers were determined based on the entropy generation minimization (EGM) approach. Parametric studies were conducted to demonstrate the application of the analytical calculation method. Optimal tube row number for different air mass flow rates, inlet air temperatures and sensible cooling loads were investigated. It was found that the optimal tube row number of a DX cooling coil was in the range of 5 - 9 under normal operating conditions. The optimal tube row number was less when the mass flow rate and inlet air temperature were increased. The tube row number increased when the sensible cooling load was increased. The exergy loss when using a non-optimal and optimal tube row numbers was compared to show the advantage of using the optimal tube row number. The decrease of exery loss ranged from around 24% to 70%. Therefore the new analytical method developed in this paper offers a good practice guide for the design of DX cooling coils for energy conservation.

关键词Optimal Tube Row Number Entropy Generation Minimization Direct Expansion (DX) Cooling Coil Building Energy Efficiency
DOI10.4236/jbcpr.2015.32006
URL查看来源
语种英语English
引用统计
文献类型期刊论文
条目标识符https://repository.uic.edu.cn/handle/39GCC9TT/12002
专题个人在本单位外知识产出
通讯作者Xia, Liang
作者单位
1.Department of Architecture and Built Environment, University of Nottingham Ningbo China, Ningbo, China
2.School of Mathematical Sciences, University of Nottingham Ningbo China, Ningbo, China
3.Department of Civil Engineering, University of Nottingham Ningbo China, Ningbo, China
推荐引用方式
GB/T 7714
Xia, Liang,Yang, Tong,Chan, Yueet al. Optimisation of Direct Expansion (DX) Cooling Coils Aiming to Building Energy Efficiency[J]. Journal of Building Construction and Planning Research, 2015, 3(2): 47-59.
APA Xia, Liang, Yang, Tong, Chan, Yue, Tang, Llewellyn, & Chen, Yung-Tsang. (2015). Optimisation of Direct Expansion (DX) Cooling Coils Aiming to Building Energy Efficiency. Journal of Building Construction and Planning Research, 3(2), 47-59.
MLA Xia, Liang,et al."Optimisation of Direct Expansion (DX) Cooling Coils Aiming to Building Energy Efficiency". Journal of Building Construction and Planning Research 3.2(2015): 47-59.
条目包含的文件
条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Xia, Liang]的文章
[Yang, Tong]的文章
[Chan, Yue]的文章
百度学术
百度学术中相似的文章
[Xia, Liang]的文章
[Yang, Tong]的文章
[Chan, Yue]的文章
必应学术
必应学术中相似的文章
[Xia, Liang]的文章
[Yang, Tong]的文章
[Chan, Yue]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。