Abstract | Non-invasive blood glucose monitoring at microwave frequencies is generally thought to be unreliable in terms of reproducibility of measurements. The failure to reproduce a blood glucose measurement from one experiment to another is in major part due to the unwanted interaction of leaky waves between the ambient environment and the blood glucose measuring device. In this work, we have overcome this problem by simply eliminating the leaky modes through the use of surface electromagnetic waves from a curved Goubau line. In the proposed methodology, a fixed volume of blood-filled skin tissue was first formed by vacuum suction and partially wound with a curved Goubau line which was coated with a 3 mm thick layer of gelatin/glycerin composite. Blood glucose levels were non-invasively determined using a network analyzer. At 4.5 GHz, a near-linear correlation exists between the measured S12 parameters and the blood glucose levels. The measured correlation was highly reproducible and consistent with the measurements obtained using the conventional invasive lancing approach. The findings of this work suggest the feasibility of non-invasive detection of left and right imbalances in the body. |
Keyword | Acu-check Goubau line Lancet Leaky waves Non-invasive blood glucose measurement Surface waves |
DOI | 10.3390/electronics8060662 |
URL | View source |
Indexed By | SCIE |
Language | 英语English |
WOS Research Area | Computer Science ; Engineering ; Physics |
WOS Subject | Computer Science, Information Systems ; Engineering, Electrical & Electronic ; Physics, Applied |
WOS ID | WOS:000475354700068 |
Scopus ID | 2-s2.0-85070699217 |
Citation statistics | |
Document Type | Journal article |
Identifier | http://repository.uic.edu.cn/handle/39GCC9TT/6761 |
Collection | Research outside affiliated institution |
Affiliation | 1.Faculty of Engineering,Vietnamese German University,Thu Dau Mot,820000,Viet Nam 2.Shenzhen Institutes of Advanced Technology,Chinese Academy of Sciences,Shenzhen,518000,China 3.Department of Electrical and Electronic Engineering,Southern University of Science and Technology,Shenzhen,I Park A7, Nanshen,518055,China |
Recommended Citation GB/T 7714 | Liu, Louis W.Y.,Kandwal, Abhishek,Cheng, Qingshaet al. Non-invasive blood glucose monitoring using a curved goubau line[J]. Electronics, 2019, 8(6). |
APA | Liu, Louis W.Y., Kandwal, Abhishek, Cheng, Qingsha, Shi, Hongjian, Tobore, Igbe, & Nie, Zedong. (2019). Non-invasive blood glucose monitoring using a curved goubau line. Electronics, 8(6). |
MLA | Liu, Louis W.Y.,et al."Non-invasive blood glucose monitoring using a curved goubau line". Electronics 8.6(2019). |
Files in This Item: | There are no files associated with this item. |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment