TitleNon-invasive blood glucose monitoring using a curved goubau line
Creator
Date Issued2019
Source PublicationElectronics
ISSN2079-9292
Volume8Issue:6
Abstract

Non-invasive blood glucose monitoring at microwave frequencies is generally thought to be unreliable in terms of reproducibility of measurements. The failure to reproduce a blood glucose measurement from one experiment to another is in major part due to the unwanted interaction of leaky waves between the ambient environment and the blood glucose measuring device. In this work, we have overcome this problem by simply eliminating the leaky modes through the use of surface electromagnetic waves from a curved Goubau line. In the proposed methodology, a fixed volume of blood-filled skin tissue was first formed by vacuum suction and partially wound with a curved Goubau line which was coated with a 3 mm thick layer of gelatin/glycerin composite. Blood glucose levels were non-invasively determined using a network analyzer. At 4.5 GHz, a near-linear correlation exists between the measured S12 parameters and the blood glucose levels. The measured correlation was highly reproducible and consistent with the measurements obtained using the conventional invasive lancing approach. The findings of this work suggest the feasibility of non-invasive detection of left and right imbalances in the body.

KeywordAcu-check Goubau line Lancet Leaky waves Non-invasive blood glucose measurement Surface waves
DOI10.3390/electronics8060662
URLView source
Indexed BySCIE
Language英语English
WOS Research AreaComputer Science ; Engineering ; Physics
WOS SubjectComputer Science, Information Systems ; Engineering, Electrical & Electronic ; Physics, Applied
WOS IDWOS:000475354700068
Scopus ID2-s2.0-85070699217
Citation statistics
Cited Times:23[WOS]   [WOS Record]     [Related Records in WOS]
Document TypeJournal article
Identifierhttp://repository.uic.edu.cn/handle/39GCC9TT/6761
CollectionResearch outside affiliated institution
Affiliation
1.Faculty of Engineering,Vietnamese German University,Thu Dau Mot,820000,Viet Nam
2.Shenzhen Institutes of Advanced Technology,Chinese Academy of Sciences,Shenzhen,518000,China
3.Department of Electrical and Electronic Engineering,Southern University of Science and Technology,Shenzhen,I Park A7, Nanshen,518055,China
Recommended Citation
GB/T 7714
Liu, Louis W.Y.,Kandwal, Abhishek,Cheng, Qingshaet al. Non-invasive blood glucose monitoring using a curved goubau line[J]. Electronics, 2019, 8(6).
APA Liu, Louis W.Y., Kandwal, Abhishek, Cheng, Qingsha, Shi, Hongjian, Tobore, Igbe, & Nie, Zedong. (2019). Non-invasive blood glucose monitoring using a curved goubau line. Electronics, 8(6).
MLA Liu, Louis W.Y.,et al."Non-invasive blood glucose monitoring using a curved goubau line". Electronics 8.6(2019).
Files in This Item:
There are no files associated with this item.
Related Services
Usage statistics
Google Scholar
Similar articles in Google Scholar
[Liu, Louis W.Y.]'s Articles
[Kandwal, Abhishek]'s Articles
[Cheng, Qingsha]'s Articles
Baidu academic
Similar articles in Baidu academic
[Liu, Louis W.Y.]'s Articles
[Kandwal, Abhishek]'s Articles
[Cheng, Qingsha]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Liu, Louis W.Y.]'s Articles
[Kandwal, Abhishek]'s Articles
[Cheng, Qingsha]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.