发表状态 | 已发表Published |
题名 | Comparison and evaluation of the Chang'E microwave radiometer data based on theoretical computation of brightness temperatures at the Apollo 15 and 17 sites |
作者 | |
发表日期 | 2017-09-15 |
发表期刊 | Icarus
![]() |
ISSN/eISSN | 0019-1035 |
卷号 | 294页码:72-80 |
摘要 | There are significant differences (in the order of 3 to 20 K) between the lunar brightness temperatures (TBs) as measured by the microwave radiometers (MRM) onboard Chang'E (CE)−1 and −2. To determine which set is more accurate, we have carried out a dataset comparison using theoretical calculations of the TBs (four frequency channels) versus local time at the Apollo 15 and 17 landing sites, where the thermal parameters are well-constrained by the in-situ measurements. Based on these parameters, we sought to constrain fits between theory and observation, as uncertainties still exist in parameters involved in the microwave transfer computation. We found that: (i) CE-1/2 TBs have almost constant biases (negative, different for different channels) from the theoretical TBs. The averaged biases for each channel are smaller for CE-1; (ii) TBs of the high frequency channels (19.35/37 GHz) show a better fit with theory than the low frequency channels. The channel 4 (37 GHz) TBs from CE-1 are consistently shifted by about 1 K from the theoretical values. Adjustments in the order of 20 K are instead needed for the two CE-2 low frequency channels (3/7.8 GHz). Based on this comparison, we conclude that the CE-1 dataset to be more accurate than CE-2 one in terms of temperature accuracy (not spatial resolution). We also offer a possible explanation for the significant TB differences between CE-1 and CE-2, and propose a possible recalibration method as a starting point towards the realignment of the two datasets. |
关键词 | Chang'e (CE) Evaluation Microwave brightness temperature (TB) Transfer model |
DOI | 10.1016/j.icarus.2017.04.009 |
URL | 查看来源 |
收录类别 | SCIE |
语种 | 英语English |
WOS研究方向 | Astronomy & Astrophysics |
WOS类目 | Astronomy & Astrophysics |
WOS记录号 | WOS:000403734700005 |
Scopus入藏号 | 2-s2.0-85019123158 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://repository.uic.edu.cn/handle/39GCC9TT/6347 |
专题 | 北师香港浸会大学 |
作者单位 | 1.Space Science Institute,Macau University of Science and Technology,Macao 2.Lunar Planetary Science Laboratory of Macau University of Science and Technology & Partner Laboratory of Key Laboratory of Lunar and Deep Space Exploration of Chinese Academy of Sciences,Macao 3.Key Laboratory of Lunar and Deep Space Exploration,National Astronomical Observatories,Chinese Academy of Sciences,Beijing,100012,China 4.Beijing Normal University-Hong Kong Baptist University United International College,Zhuhai,519000,China |
推荐引用方式 GB/T 7714 | Hu, Guo Ping,Chan, Kwing L.,Zheng, Yong Chunet al. Comparison and evaluation of the Chang'E microwave radiometer data based on theoretical computation of brightness temperatures at the Apollo 15 and 17 sites[J]. Icarus, 2017, 294: 72-80. |
APA | Hu, Guo Ping, Chan, Kwing L., Zheng, Yong Chun, Tsang, Kang T., & Xu, Ao Ao. (2017). Comparison and evaluation of the Chang'E microwave radiometer data based on theoretical computation of brightness temperatures at the Apollo 15 and 17 sites. Icarus, 294, 72-80. |
MLA | Hu, Guo Ping,et al."Comparison and evaluation of the Chang'E microwave radiometer data based on theoretical computation of brightness temperatures at the Apollo 15 and 17 sites". Icarus 294(2017): 72-80. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论