Details of Research Outputs

TitleRapid determination of trace EDTA in wines and beers by LC-MS/MS
Creator
Date Issued2016-10-01
Source PublicationLWT - Food Science and Technology
ISSN0023-6438
Volume72Pages:485-491
Abstract

A novel method for quantitative analysis of ethylenediaminotetracetic acid (EDTA) in wines and beers by liquid chromatography coupled to tandem mass spectrometry has been developed. Positive-ion mode was applied as the scan mode, amine species were firstly used as the derivatization reagents of EDTA, and phenylboronic acid was used to react with maltose to eliminate its matrix interference. Primary amines could efficiently eliminate the interference from metal ions (Fe(III) and Cu(II)). The responsive intensity of EDTA with amine derivatization could be improved over 300 times than that without adding amine species. The recovery rate was significantly increased to 104.1% after adding phenylboronic acid at 20.0 mg/L as compared to the control spike-and-recovery experiment results (1.3-1.7%) of beer samples without adding phenylboronic acid. The validated method showed excellent detection sensitivity (0.001 mg/L for LOD (limit of detection) and 0.004 mg/L for LOQ (limit of quantification)) with satisfactory recovery rates (76.0%-97.2%), and good precision (1.40-5.40% RSD values). The optimized method has been satisfactorily applied to the analysis of actual wine and beer samples. It can be proposed as a powerful analytical method of EDTA in wines and beers, and can even be adapted to detect other chelates and polydentate compounds.

KeywordMatrix interference Metal-chelation Novel method validation Sensitivity Tandem mass spectrometry
DOI10.1016/j.lwt.2016.05.019
URLView source
Citation statistics
Cited Times:8[WOS]   [WOS Record]     [Related Records in WOS]
Document TypeJournal article
Identifierhttp://repository.uic.edu.cn/handle/39GCC9TT/1430
CollectionFaculty of Science and Technology
Corresponding AuthorXu, Baojun
Affiliation
1.Guangdong Inspection and Quarantine Technology Center,Guangzhou, Guangdong,510623,China
2.College of Food Science and Engineering,South China Agricultural University,Guangzhou, Guangdong,510642,China
3.Guangdong Key Laboratory of Import and Export Technical Measures of Animal,Plant and Food,Guangzhou, Guangdong,510623,China
4.Food Science and Technology Program,Beijing Normal University-Hong Kong Baptist University United International College,Zhuhai, Guangdong,519085,China
Corresponding Author AffilicationBeijing Normal-Hong Kong Baptist University
Recommended Citation
GB/T 7714
Wei,Xiaoqun,Zhuang, Linzhou,Wu, Chaominet al. Rapid determination of trace EDTA in wines and beers by LC-MS/MS[J]. LWT - Food Science and Technology, 2016, 72: 485-491.
APA Wei,Xiaoqun, Zhuang, Linzhou, Wu, Chaomin, Chen, Wenrui, Li, Zhiyong, & Xu, Baojun. (2016). Rapid determination of trace EDTA in wines and beers by LC-MS/MS. LWT - Food Science and Technology, 72, 485-491.
MLA Wei,Xiaoqun,et al."Rapid determination of trace EDTA in wines and beers by LC-MS/MS". LWT - Food Science and Technology 72(2016): 485-491.
Files in This Item:
There are no files associated with this item.
Related Services
Usage statistics
Google Scholar
Similar articles in Google Scholar
[Wei,Xiaoqun]'s Articles
[Zhuang, Linzhou]'s Articles
[Wu, Chaomin]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wei,Xiaoqun]'s Articles
[Zhuang, Linzhou]'s Articles
[Wu, Chaomin]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wei,Xiaoqun]'s Articles
[Zhuang, Linzhou]'s Articles
[Wu, Chaomin]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.